What is an Oil Surge Relay (OSR)? – A Complete Guide

An Oil Surge Relay, or OSR, is a type of mechanical relay. It operates in response to a sudden oil surge. Need for Separate Diverter Tank Every modern power transformer includes an On-Load Tap Changer (OLTC). During tap-changing operations, some arcing always occurs at the diverter switch contacts. It is desirable to change tap positions … Read more

What is XLPE or Cross Linked Polyethylene

XLPE stands for Cross Linked Polyethylene. This is a type of polymer insulation widely used in electrical power cables, especially in high voltage (HV) and extra-high voltage (EHV) applications. It is derived from polyethylene but has been chemically modified to improve its thermal, mechanical, and electrical properties. Key Features of XLPE Cross-Linking Process: In standard … Read more

Nitrogen Injection Fire Protection System (NIFPS or NIFPES)

Nitrogen Injection Fire Protection System (NIFPS or NIFPES)

The Nitrogen Injection Fire Protection System (NIFPS) prevents and extinguishes fires in oil-filled transformers. Thereby, it safeguards critical power infrastructure. We also commonly call it the Nitrogen Injection Fire Prevention & Extinguishing System (NIFPES). This system operates on a “drain and stir” principle, effectively mitigating fire hazards through a coordinated sequence of actions. Working Principle … Read more

Testing of Lightning Arrester

Type Tests on a Lightning Arrester as per IS 3070 Routine Tests on a Lightning Arrester as per IS 3070 Routine Tests on a Surge Monitor Acceptance Tests on a Lightning Arrester Acceptance Test on a Surge Monitor

Stage Inspection of a Transformer

A power transformer has high cost, large size, and complex design. So, identifying defects at the final stage of manufacturing can lead to significant delays, expenses, and operational challenges. Therefore, standards always recommend performing different tests and inspections during various stages of manufacturing. That means the standards always prefer to perform stage inspections of a … Read more

Testing of High Voltage Isolators

Type Tests of Isolators as per IS 9921 (Part 4) – 1985 The type tests of isolators are conducted to ensure that the isolators meet the performance criteria under standard operating conditions. According to IS 9921 (Part 4) – 1985, the type tests of isolators can be broadly categorized into the following: These type tests … Read more

Questions on Voltage Transformer – A Complete Session

What is the Rated Voltage Factor in voltage transformers, and how is it determined? This is the ratio of the maximum operating voltage to the rated primary voltage of the PT. We have to multiply this factor by the primary rated voltage. This determines the maximum operating voltage of the PT. In other words, this … Read more

Top Questions on HV Lightning Arresters – A Complete Session

What is the definition of the rated voltage of a lightning arrester? As per IS 3070, the definition of the “rated voltage of a Lightning Arrester” is given below.The maximum permissible r.m.s. value of power-frequency voltage between the line and earth terminal under temporary over-voltage conditions for a duration of 10 seconds as established in … Read more

Parameters of a Transformer (10MVA 66/11KV Transformer)

The clearance requirements for HV and LV terminals in the air are as follows:For 66 kV side, the phase-to-phase and phase-to-earth clearance should be 700 mm, and 660 mm respectively.For 12 kV side, the phase-to-phase and phase-to-earth clearance should be 280 mm, and 140 mm respectively. The following points should be noted for designing winding … Read more